- Warehouse complexes. Industrial facilities
General view of a gate with a drive from the side (drive on the left/drive on the right).
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | 1,600–5,700 |
B, mm Opening width | 1,800–5,800 |
General view of a gate with a drive from the front (front left/front right).
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | 1,600–5,700 |
B, mm Opening width | 1,800–5,800 |
Parameter | Value | Notes |
---|---|---|
Wind load, Pa | CLASS1 (up to 82) | For gates up to 6,000 × 6,000 mm |
Wind load, Pa | CLASS2 (up to 90) | For gates up to 5,000 × 5,000 mm |
Opening speed, m/s | 2.0 | For gates up to 3,000 × 3,000 mm |
Opening speed, m/s | 1.5 | For gates up to 5,000 × 5,000 mm |
Opening speed, m/s | 1.0 | For gates up to 6,000 × 6,000 mm |
Closing speed, m/s | 0.5 | |
Operating temperature range, °С | -30...+50 | When using the rack and drive heating system; when operating in a temperature range of -16...-30 °C, the gate design does not have reinforcement on the leaf, and transparent sections cannot be installed: the “Security Profile” option is not available |
Power, W | 1,500 | |
IP protection class | IP54 | End positions are tracked by encoder |
Supply voltage, V | 220 V / 50 Hz | Single phase |
Supply voltage, V | 380 V / 50 Hz | Three-phase |
Number of cycles | 1,500,000 | Depends on operating conditions |
Wind load, Pa | CLASS3 (up to 120) | For gates up to 3,000 × 3,000 mm |
Wind load resistance for SpeedRoll series doors is given for the door in the closed position. Gates are not used in places with unstable and increased wind loads caused by natural or man-made factors, such as:
- buildings located on sea coasts or in the mountains;
- multi-level heated underground parking lots with multiple entrances and exits;
- production with powerful supply and exhaust ventilation;
- in buildings of complex configuration with many gate openings, where strong drafts may occur. If one or more of the above factors are present, it is recommended to use a SpeedFold series door or a HSSD series spiral door.
To ensure reliable and uninterrupted operation of the gate, it is recommended to carry out regular technical inspection and maintenance.
Manual opening and closing of the gate is done using a crank.
Do not subject the gate to impacts or interfere with its free opening and closing.
Do not allow the PVC sheet guide to get dirty.
It is prohibited to stand in the opening while the gate is opening and closing to avoid injury.
Make sure that there are no foreign objects in the opening when opening and closing the gate.
For gates installed outside the building and used at temperatures below -15 °C, operation of the door leaf with windows is not allowed.
The self-healing function of the door leaf in the guides is used to operate the gate in emergency conditions, in the event of an unintentional collision with a vehicle; it is not intended to work when the door leaf is deliberately and systematically knocked out of the guides. The functionality of the function is ensured by the possibility of the “zipper”, installed on the door leaf from plastic guides, coming out. The functionality of the function cannot be ensured in the event of impacts that exceed the strength parameters of the individual components of the web and system elements. For example, in the event of a collision with a road surface at high speed, impacts with sharp objects, impacts on the top of the gate with raised forks of a forklift, etc.
The DoorHan concern loads gates onto trucks using a hydraulic crane or forklift with a fork of at least 2 m. The buyer or installer must provide the same equipment for moving the packaged gates. The plug should fit under the wooden pallet provided by the manufacturer and protrude from the other side. When using a crane or other lifting equipment, it is recommended that you use slings of adequate lifting capacity.
The buyer is provided with a performance guarantee for high-speed rolling gates produced by the DoorHan concern for a period of 1 year for retail and for a period of 2 years for dealer orders from the date of purchase.
General view of a gate with a drive from the side (drive on the left/drive on the right).
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | 1,600–5,700 |
B, mm Opening width | 1,800–5,800 |
General view of a gate with a drive from the front (front left/front right).
Symbol, parameter name | Calculation formula |
---|---|
H, mm Opening height | 1,600–5,700 |
B, mm Opening width | 1,800–5,800 |
Parameter | Value | Notes |
---|---|---|
Wind load, Pa | CLASS1 (up to 82) | For gates up to 6,000 × 6,000 mm |
Wind load, Pa | CLASS2 (up to 90) | For gates up to 5,000 × 5,000 mm |
Opening speed, m/s | 2.0 | For gates up to 3,000 × 3,000 mm |
Opening speed, m/s | 1.5 | For gates up to 5,000 × 5,000 mm |
Opening speed, m/s | 1.0 | For gates up to 6,000 × 6,000 mm |
Closing speed, m/s | 0.5 | |
Operating temperature range, °С | -30...+50 | When using the rack and drive heating system; when operating in a temperature range of -16...-30 °C, the gate design does not have reinforcement on the leaf, and transparent sections cannot be installed: the “Security Profile” option is not available |
Power, W | 1,500 | |
IP protection class | IP54 | End positions are tracked by encoder |
Supply voltage, V | 220 V / 50 Hz | Single phase |
Supply voltage, V | 380 V / 50 Hz | Three-phase |
Number of cycles | 1,500,000 | Depends on operating conditions |
Wind load, Pa | CLASS3 (up to 120) | For gates up to 3,000 × 3,000 mm |
Wind load resistance for SpeedRoll series doors is given for the door in the closed position. Gates are not used in places with unstable and increased wind loads caused by natural or man-made factors, such as:
- buildings located on sea coasts or in the mountains;
- multi-level heated underground parking lots with multiple entrances and exits;
- production with powerful supply and exhaust ventilation;
- in buildings of complex configuration with many gate openings, where strong drafts may occur. If one or more of the above factors are present, it is recommended to use a SpeedFold series door or a HSSD series spiral door.
To ensure reliable and uninterrupted operation of the gate, it is recommended to carry out regular technical inspection and maintenance.
Manual opening and closing of the gate is done using a crank.
Do not subject the gate to impacts or interfere with its free opening and closing.
Do not allow the PVC sheet guide to get dirty.
It is prohibited to stand in the opening while the gate is opening and closing to avoid injury.
Make sure that there are no foreign objects in the opening when opening and closing the gate.
For gates installed outside the building and used at temperatures below -15 °C, operation of the door leaf with windows is not allowed.
The self-healing function of the door leaf in the guides is used to operate the gate in emergency conditions, in the event of an unintentional collision with a vehicle; it is not intended to work when the door leaf is deliberately and systematically knocked out of the guides. The functionality of the function is ensured by the possibility of the “zipper”, installed on the door leaf from plastic guides, coming out. The functionality of the function cannot be ensured in the event of impacts that exceed the strength parameters of the individual components of the web and system elements. For example, in the event of a collision with a road surface at high speed, impacts with sharp objects, impacts on the top of the gate with raised forks of a forklift, etc.
The DoorHan concern loads gates onto trucks using a hydraulic crane or forklift with a fork of at least 2 m. The buyer or installer must provide the same equipment for moving the packaged gates. The plug should fit under the wooden pallet provided by the manufacturer and protrude from the other side. When using a crane or other lifting equipment, it is recommended that you use slings of adequate lifting capacity.
The buyer is provided with a performance guarantee for high-speed rolling gates produced by the DoorHan concern for a period of 1 year for retail and for a period of 2 years for dealer orders from the date of purchase.