- For street roller doors
- For garage roller doors
Parameter | Value | Notes |
---|---|---|
Supply voltage, V | 380–400 V / 50/60 Hz | |
Motor rotational speed, rev/min | 1 400 / 720 | |
Power, W | 800 / 1 500 | |
Torque, Nm | 200 / 500 | |
Operating temperature range, °С | -30...+55 / -20…+45 | |
Thermal protection, °С | 120 | |
Weight, kg | 25 / 35 |
1. Make sure that the place of use corresponds to the characteristics of the drive in terms of its climatic conditions.
2. Do not install the equipment in rooms with flammable substances or hazardous environments.
3. Make sure that there will be no pinching of objects between the moving and fixed parts of the drive when the door moves.
4. Use only original accessories to avoid damage to the drive.
5. Do not leave the electric operator in a disengaged state.
6. Do not use the drive if repair or adjustment is necessary.
7. Make sure that there are no foreign objects in the area of the electric drive before starting it.
8. Passage is allowed only when the roller shutter is stopped and the drive is turned off.
9. Do not let children use the drive and accessories.
10. Do not make changes to the automation.
The emergency drive allows the door leaf to be lifted manually.
The main and backup limit switches are used in the design of the drive to increase the accuracy of the door stop.
The drive control unit has compact dimensions. All necessary connections are made at the production stage.
High class of dust and moisture protection - IP54.
The buyer is provided with a 3-year drive performance guarantee from the date of purchase. Dealers have the right to change the warranty period.
Parameter | Value | Notes |
---|---|---|
Supply voltage, V | 380–400 V / 50/60 Hz | |
Motor rotational speed, rev/min | 1 400 / 720 | |
Power, W | 800 / 1 500 | |
Torque, Nm | 200 / 500 | |
Operating temperature range, °С | -30...+55 / -20…+45 | |
Thermal protection, °С | 120 | |
Weight, kg | 25 / 35 |
1. Make sure that the place of use corresponds to the characteristics of the drive in terms of its climatic conditions.
2. Do not install the equipment in rooms with flammable substances or hazardous environments.
3. Make sure that there will be no pinching of objects between the moving and fixed parts of the drive when the door moves.
4. Use only original accessories to avoid damage to the drive.
5. Do not leave the electric operator in a disengaged state.
6. Do not use the drive if repair or adjustment is necessary.
7. Make sure that there are no foreign objects in the area of the electric drive before starting it.
8. Passage is allowed only when the roller shutter is stopped and the drive is turned off.
9. Do not let children use the drive and accessories.
10. Do not make changes to the automation.
The emergency drive allows the door leaf to be lifted manually.
The main and backup limit switches are used in the design of the drive to increase the accuracy of the door stop.
The drive control unit has compact dimensions. All necessary connections are made at the production stage.
High class of dust and moisture protection - IP54.
The buyer is provided with a 3-year drive performance guarantee from the date of purchase. Dealers have the right to change the warranty period.